MKS-UM - Dosimeter-radiometer universal with GPS

Be the first to review this product

Compliant with the international standards MIL-STD-810G and MIL-STD-461F.
Compliant with the international standards ІЕС 60846 and ІЕС 60325.
Measurement of alpha, beta, gamma and X-ray radiation.
Integrated dual-system GPS / GLONASS receiver.
High protection rating IP67.
Integral solar battery.

Availability: In stock

$8,900
$8,900

This product is shipped by airmail

We'll send product in 2 days. Read more...

Contact us now for more info about our products.

Return purchased items, get your money back.

Buy this product and receive full support.

Description

Details

Under the order - manufacture of 30-60 days

Wide radiation detection device in the field. Designed based on the device  MKS-U, which is great-proven in harsh desert conditions during the peacekeeping mission in the Middle East.

In addition to gamma and beta radiation device may further measure the alpha radiation. It added the ability to archive measurement results with reference to the coordinates of the area thanks to the integrated dual-system GPS / GLONASS receiver. The device uses a lithium-ion battery is missing from a memory effect. The display shows the statistical error of the measurements. The presence of analog radiation intensity indicator facilitates the localization of radiation sources. The high degree of IP67 protection and a rubber protective pouch allow use in harsh climatic conditions. Due to the reduced weight and size parameters to operate the instrument has become even more comfortable.

ISS-UM measures the power of gamma rays from the background to the emergency levels.

The presence detector can measure remote emergency power levels of gamma radiation at a distance of 30 m. The device operates in conditions of atmospheric precipitation, dusty atmosphere and remote detector when immersed into water to a depth of 0.5 m.

Charging the rechargeable battery device by an integrated battery charger by its own geliobatarei, from a car battery or commercial power.

The device has a non-volatile memory, and the recorded results can be viewed on the display or transferred to a computer.

It complies with the requirements of international standards

  • IES 60846
  • IES 60325.

appointment

  • Power measurement of ambient dose equivalent (DER) of gamma and X-ray radiation.
  • Measurement of ambient dose equivalent (EDA) and gamma ray radiation.
  • Measurement of surface flux density and surface activity of beta radiation particles.
  • Measurement of surface flux density and surface activity of alpha-particle radiation.
  • storage time measurement of the ambient dose equivalent of gamma and X-ray radiation.
  • Archiving of measurement results with reference to the coordinates of the area.

industry application

  • Radiological laboratories.
  • Radioactive waste storage.
  • Nuclear power.
  • Strong structure.
  • Ministry of Emergency Situations and Civil Defense.

Features

  • Ability measurements DER gamma-radiation with the built-in remote detector.
  • Automatic selection of measurement intervals and ranges.
  • The presence of signaling of each detected gamma ray, or beta particles.
  • Backlit display and controls in the dark.
  • Charging a lithium-ion battery using a charger unit built by: Multilevel indication of power supply discharge.
    • geliobatarei own,
    • 12V car battery,
    • industrial network 220V / 50Hz using an inverter.
  • Ability to work in conditions of atmospheric precipitation, dusty atmosphere (degree of protection IP67) and remote wide-range detector immersed into water to a depth of 0.5 m.
  • Measurement of emergency DER levels of gamma radiation with the placement of the remote wide-range detector at a distance of 30 m.
  • Analog indicator of radiation intensity.
  • Recording in the nonvolatile memory with the transfer to the PC via an infrared port 1500 measurements with reference to the coordinates of the area (integrated GPS / GLONASS receiver).
  • Review of the recorded measurement results on the display.
  • Ability to work with the device in personal protective equipment (rubber gloves).
  • Wide operating temperature range (-40 ... + 50 ° C).
  • Resistance indicator of temperature to + 95 ° C.

The instrument uses

  • Discharge Geiger-Muller counter without reverse counting response;
  • Silicon detector beta radiation;
  • Scintillation gamma ray detector (CsI-scintillator-photodiode) for emergency levels of gamma radiation.

Basic specifications

Measurement parameters of gamma and X-radiation
Range measurements DER gamma and X-ray radiation via a combo box-01 detection DBCE 0.1 mSv / h ... 10 Sv / h
Range measurements DER gamma and X-ray radiation via a combo box-02 detection DBCE 0.1 mSv / h ... 2 Sv / h
DER measurement range of gamma and X-ray radiation by means of a wide-range remote detector Sv / h 0.01 ... 100
Measurement range EDA gamma and X-ray radiation with the built-in remote detector and relative basic error mSv

 

%

0,001 ... 9999

 

± 15

Relative DER main measurement error in the calibration for 137Cs: 
- for combined detection units DBCE DBCE-01 and-02 ± (15 + 2 / N * (10))%, where H * (10) - the numerical value of the measured DER equivalent mSv / h
- for external wide-range detector ± (15 + 200 / H * (10))%, where H * (10) - the numerical value of the measured DER equivalent mSv / h
Energy measurement range MэB 0.05 3.0 ...
accumulation time measurement range and measurement precision EDA 1min ... 100h;
± 1min per 100h
Measurement of the beta radiation
the surface density of the measurement range of flux particles of beta radiation detection by the combined blocks 01 and DBCE DBCE-02 1 / (cm2 · min) 10 ... 200 000
The measuring range of the surface activity of beta radiation particles by combined detection units DBCE DBCE-01 and-02 Bq / cm2 0 ... 13500
Energy measurement range via the combined unit 01 detecting DBCE MэB 0.3 ... 3.0
Energy measurement range via the combined unit 02 detecting DBCE MэB 0.15 3.0 ...
Permissible relative basic error measurement surface beta radiation flux density of the particles in the calibration of 90Sr + 90Y ± (20 + 200 / φβ)%, where φβ - the numerical value of measured surface flux density of beta radiation, equivalent portions ./ (cm² · min)
Permissible relative basic error measurement surface activity of beta radiation particles during calibration of 90Sr + 90Y ± (20 + 10 / V)%, where B - the numerical value of measured surface activity of beta-emitting radionuclides, expressed in Bq / cm²
Measurement of alpha radiation parameters
The measuring range of the surface of alpha-particle radiation flux density in the combined unit 02 detecting DBCE 1 / (cm2 · min) 10 ... 300 000
The measuring range of the surface activity of alpha-particle radiation using a combined unit 02 detecting DBCE Bq / cm2 0 ... 13500
Energy measurement range via the combined unit 02 detecting DBCE MONE 4.0 and more
Permissible relative basic error measurement surface alpha radiation flux density of the particles in the calibration of 239Pu ± (15 + 300 / φ)%, where φ - the numerical value of measured surface flux density of alpha radiation equivalent portions ./ (cm² · min)
Permissible relative basic error measurement surface activity of alpha particle radiation during calibration of 239Pu ± (15 + 15 / A)%, where A - the numerical value of the measured surface activity of alpha-emitting radionuclides, expressed in Bq / cm²
continuous operating time when powered from the lithium ion battery size 26650 clock 100
Rabochih temperature range (digital indicator) FROM -40 ... + 50
(-40 ... + 95)
Masca console without cover kg 1.3
Overall dimensions of the console without cover mm 156x120x60
Masca DBCE-detection unit 01 without cable kg 0.3
Dimensions detection unit BDKS-01 without cable mm 165 × 48
Masca DBCE-detection unit 02 without cable kg 0.6
Dimensions detection unit BDKS-02 without cable mm 160x73x43
Masca remote wide-range detector without cable kg 0.1
Overall dimensions of the broadband remote detectors without cable mm Ø34 × 50
The weight of a briefcase kg 9
set dimensions in a case mm 554x420x123

Contents of delivery

  • Panel with non-detachable combined gamma, beta detecting unit.
  • Combined gamma-beta detection unit BDKS-01.
  • Combined gamma alpha-beta-DBCE detection unit 02.
  • Geliobatareya.
  • Short telescopic rod for detecting unit.
  • for charging cable from the vehicle battery 12 (10m).
  • Adapter 220/12 B.
  • Lithium-ion battery size 26650.
  • Earphone.
  • Case.
  • Manual.
  • Form.
  • Set of remote wide-range detection unit: external gamma detector with a 30-meter cable 5 meter telescopic rod with a handle-arm for winding a cable cover for the telescopic rod.
  • Spare parts.
  • Exchange infrared port adapter and software (on request).

The device can be equipped on demand.

Reviews

Write Your Own Review

Only registered users can write reviews. Please, log in or register

Tags

Tags

Use spaces to separate tags. Use single quotes (') for phrases.